Friday, May 20, 2016

Huawei S5700 Port Numbering Conventions


Huawei S5700 Port Numbering Conventions
Physical ports are numbered in the following way:
A single switch uses slot ID/subcard ID/port sequence number to identify physical ports.
  • Slot ID: indicates the slot where the switch is located. The value is 0.
  • Subcard ID: indicates the ID of a subcard.
  • Port sequence number: indicates the sequence number of an port on the switch.
A stacked switch uses Stack ID/subcard ID/port sequence number to identify physical ports.
  • Stack ID: indicates the ID of a stacked switch. The value ranges from 0 to 8.
  • Subcard ID: indicates the ID of a subcard.
  • Port sequence number: indicates the sequence number of an port on the switch.
Huawei S5700 Series Port numbering conventions

Port Numbering Diagram
Description
There are two rows of service ports on the device. These ports are numbered from bottom to top and left to right, starting from 1.
For example, the port on the top left is numbered 0/0/2.

CSFP port numbering conventions

Port Numbering Diagram
Description

For example, an S5700-52X-LI-48CS-AC has 24 physical ports located in two rows of service ports, 12 ports in each row. When all the ports have SFP optical modules installed, the ports are numbered as follows:
The ports in the lower row are numbered starting with 3 from left to right, with an increment of 4.
The ports in the upper row are numbered starting with 2 from left to right, with an increment of 4.
For example, with SFP optical modules installed, the first port at the lower left of the panel is numbered 0/0/3; the second port at the lower left is numbered 0/0/7; the first port at the upper left is numbered 0/0/2; the second port at the upper left is numbered 0/0/6.

When all the ports have CSFP optical modules installed, each port functions as two ports. The switch has a total of 48 ports in this case. These ports are numbered starting with 1 from bottom to top, and left to right.
For example, if a CSFP optical module is installed on the first port at the lower left, the port is split into two ports numbered 0/0/1 and 0/0/3. If a CSFP optical module is installed on the first port at the upper left, the port is split into two ports numbered 0/0/2 and 0/0/4.

If some ports on the switch use CSFP optical modules and some use SFP optical modules, the ports are numbered following the perspective numbering conventions.
Assume that the first port at the lower left uses a CSFP optical module and the second port at the upper left uses an SFP optical module. In this case, the two ports derived from the first CSFP port are numbered 0/0/1 and 0/0/3, and the second SFP port is numbered 0/0/6.


Huawei S5700 Switch naming conventions





NOTE:
The device names in this figure are used as examples and do not represent specific devices.

Huawei S5700 serious switch naming convention description

Identifier
Description
A
Switch
B
  • 6: 10GE downlink ports
  • 5: GE downlink ports
  • 3: Layer 3 switch with 100M downlink ports
  • 2: Layer 2 switch with 100M downlink ports
C
7: Enterprise series switch
D
Product sub-series (such as 00 or 10)
E
Resale model

NOTE:
If the letter S is not displayed, this model is a non-resale model.
F
Maximum number of ports

NOTE:
On an S5710-EI switch (such as S5710-28C-EI), this field indicates the number of fixed ports on the switch.
G
Uplink port type:
  • C: The product can use an extended card to provide uplink ports.
  • X: The product has fixed 10GE uplink ports.
  • TP: The uplink ports of the product are combo ports comprised of optical and electrical ports.
  • P: The uplink ports of the product are fixed GE optical ports.

NOTE:
If this field is not included, the switch has no uplink port.
H
Power over Ethernet (PoE) model

NOTE:
If this field is not included, the switch does not support PoE.
I
Device type
  • LI: lightweight version
  • SI: standard version
  • EI: enhanced version
  • HI: high-level version, which supports high-performance operation, administration, and maintenance (OAM) and built-in real-time clock (RTC)
J
Downlink port type:
  • 24S: 24 downlink SFP optical ports
  • 48CS: 48 downlink compact SFP (CSFP) optical ports

NOTE:
If this field is not included, all the downlink ports of the switch are electrical ports.
K
Power supply type:
  • AC: switch using alternating current power supply
  • DC: switch using direct current power supply
  • BAT: battery LAN switch


Huawei switch naming rules - huaweiproducts


Huawei switch naming rules

Huawei switch naming rules
LI: Lite software Image, the weak characteristic version. 
SI: Standard software Image, the Standard Version
EI: Enhanced software Image, the enhanced version, including some advanced features. 
HI: Hyper software Image, the advanced version.
Z: no uplink interface; (new product does not allow this)
G: uplink GBIC interface;
P: uplink SFP interface;
T: uplink RJ45 interface;
V: uplink VDSL interface;
W: uplink can be equipped with WAN interface;
C: uplink interface matching;
M: uplink interface for multimode optical interface;
S: uplink interface for single-mode optical interface;
F: the downstream
interface as the
template board, pluggable optical interface board, andelectrical
interface board. Mainly for compatibility with
3526F, 3526EF, 3552F, named after
theold products
At the same time, uplink interface is a variety of interface type.
Note: Combo port is not displayed in the naming rules.